APC AP8632, Commutable, 0U, verticale, Noir, 24 sortie(s) CA, NEMA L5-20R
Fabricant:
AMERICAN POWER CONVERSION
Numéro de produit:AP8632
Garantie du fabricant:2 années
Voir la fiche produit sur le site du fabricant.APC AP8632, Commutable, 0U, verticale, Noir, 24 sortie(s) CA, NEMA L5-20R
APC AP8632. Types de PDU: Commutable, Capacité du rack: 0U, Montage: verticale. Nombre de prises en sortie: 24 sortie(s) CA, Types de sortie AC: NEMA L5-20R, Prise mâle: NEMA L5-30P. Longueur de câble: 3 m, Certification: cUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1, UL Listed. Tension nominale à l'entrée: 100 - 120 V, Intensité (max.): 30 A, Fréquence d'entrée AC: 50 - 60 Hz. Dimensions (LxPxH): 55 x 51 x 1829 mm, Poids: 8,05 kg
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by Struxureware for Data Centers using Data Center Expert and Data Center Operations with Capacity and Change modules.
Includes : Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by Struxureware for Data Centers using Data Center Expert and Data Center Operations with Capacity and Change modules.
Includes : Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable