Tripp Lite PDUMH15HVAT power distribution unit (PDU)

Manufacturier:

TRIPP LITE

Product Number:

PDUMH15HVAT

Manufacturer Warranty:

2-year limited

See the product sheet on the manufacturer's website.

    607.00 $ 607.00 $ 607.0 CAD

    607.00 $

    This combination does not exist.

    Add to Cart
    Non disponible en ligne
    Seulement 2 available online

    2 2.4kW Single-Phase ATS/Metered PDU, 200 240V Outlets (10 C13), 2 C14 Inlets, 3


    Tripp Lite PDUMH15HVAT 2.4kW Single-Phase Local Metered Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA. PDU types: Metered, Switched, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 10 AC outlet(s), AC outlet types: C14 coupler, Power plug: IEC 320. LED indicators: Status, Cable length: 3.66 m, Certification: TAA. Nominal input voltage: 200-240 V, Maximum current: 10 A, AC input frequency: 50 - 60 Hz. Width: 439.9 mm, Depth: 367 mm, Dimensions (WxDxH): 440 x 367 x 43.4 mm

    The PDUMH15HVAT 2–2.4kW Single-Phase 200–240V Local Metered Automatic Transfer Switch / ATS PDU enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features 10 C13 outlets.

    Dual 3.6-meter input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources in a nominal voltage range from 200–240V. Plug lock inserts prevent cords from accidental disconnection. The PDUMH15HVAT constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 2–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.

    Built-in slot supports the optional WEBCARDLX (sold separate), which turn the PDUMH15HVAT into a switched PDU by allowing remote access to the PDU for power monitoring, configuration, outlet control and notifications via web browser, SSH, telnet or SNMP. Digital ammeter monitors total output current. LEDs display outlet on/off status and input power status on primary and secondary inputs.

    Primary and Secondary Inputs for Power Redundancy
    Enables redundant power for network devices with non-redundant power supply configurations
    Dual 3.6 m input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources
    10 C13 outlets

    Automatic Transfer Switching
    Dynamic solid-state (TRIAC) automatic transfer switching
    Switches to secondary power source if primary source fails or becomes unstable
    2–5 ms transfer time ensures uninterrupted operation of connected equipment
    Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source

    Digital Load Meter
    Easy-to-read ammeter displays total current used by connected equipment

    LED Indicators
    Individual LEDs display outlet on/off status and input power status on primary and secondary inputs

    Advanced Network Monitoring Options
    Built-in card slot accommodates SNMPWEBCARD and WEBCARDLX accessories (sold separately)
    Optional cards create a switched PDU by allowing remote access for power monitoring, configuration, outlet control and notification via web browser, SSH, telnet or SNMP

    Mounts Horizontally in 1U of Rack Space
    Compatible with EIA-standard 19 in. racks

    TAA-Compliant